Sign In | Join Free | My chinacsw.com |
|
Brand Name : HengAnshun
Model Number : ZW32-12(F)+GW9-10
Place of Origin : China
MOQ : 1set+3units
Price : USD2135/unit Based on EXW
Supply Ability : 1000 units/month
Delivery Time : 10 work days
Packaging Details : Export wooden case packing
Rated Current : 630A/1250A
Mechanical Life : 10000 times
Quantity : 4 (1set+3units)
Application : Substation
Max. Temperature : 70℃
Min. Temperature : -40℃
630A 1250A High Voltage Electrical Sectionalizer With Zero-Sequence Sensors Matching With Outdoor Hookstick
Product Description:
The ZW32-12 electrical sectionalizer is specifically designed for outdoor environments. It features enhanced durability and weather resistance, allowing it to withstand various harsh weather conditions such as rain, humidity, and extreme temperatures. This ensures reliable operation and longevity in outdoor installations.
It is capable of effectively breaking and closing load currents, overload currents, and short circuit currents in electronic systems. It provides reliable interruption and switching operations, ensuring the safety and proper functioning of the electrical system.
In addition to substations, the ZW32-12 electrical sectionalizer finds extensive application in industrial and mining enterprises. It offers reliable protection and control in the distribution systems of these facilities, safeguarding motors, transformers, and other electrical equipment from overcurrents and short circuits. This contributes to maintaining a stable and secure power supply in industrial and mining operations.
It is specifically designed to handle frequent operations in rural power grids. It serves as a sectional switch, allowing for efficient segmentation of the power grid. When equipped with a controller, it enables distribution network automation, improving the reliability and efficiency of the rural power system.
With the installation of a controller, the ZW32-12 electrical sectionalizer can seamlessly integrate into power grid operations. It enables remote monitoring, control, and automation of the distribution network, optimizing system performance and facilitating efficient energy management.
Controller Introduction:
1.Advanced Communication and Remote Monitoring: The ZW32-12 electrical sectionalizer is equipped with a 485/232 communication interface, allowing for seamless integration into monitoring systems. It can also be connected through optical fiber or wireless communication for remote monitoring. This enables real-time monitoring of the circuit breaker's status, performance, and fault conditions, facilitating proactive maintenance and efficient troubleshooting.
2.Acceleration Function after Reclosing: In the event of a permanent fault, the ZW32-12 electrical sectionalizer features an automatic acceleration tripping function. This means that if the fault persists after reclosing, the circuit breaker will automatically trip with increased speed, providing enhanced protection against persistent faults and minimizing potential damage to the system.
3.Adjustable Reclosing Delay Time: The ZW32-12 electrical sectionalizer allows for adjustment of the reclosing delay time. This feature provides flexibility in configuring the reclosing operation based on the specific requirements of the power system. It enables customization to optimize the system's response to different fault scenarios and improve overall system reliability.
4.Anti-Misoperation Design and Anti-Jump Function: The ZW32-12 electrical sectionalizer incorporates an anti-misoperation design for the jump closing circuit. This design prevents accidental or unintended closure of the circuit breaker. Additionally, it includes an anti-jump function, which ensures that the circuit breaker remains in a stable closed position, reducing the risk of sudden tripping due to external factors.
5.Fault Discrimination with Zero-Sequence Current: The ZW32-12 electrical sectionalizer is equipped with the ability to distinguish between in-zone and out-of-zone faults using zero-sequence current analysis. This allows for accurate fault discrimination, enabling faster and more precise fault isolation and minimizing the impact on the power system.
6.Remote Control Switch for Misoperation Prevention: The ZW32-12 electrical sectionalizer incorporates a remote control switch with a specific design to prevent misoperations. This feature ensures that remote operations are carried out safely and reduces the risk of accidental tripping or unintended actions.
Structure:
1.Vacuum Interrupter: The vacuum interrupter is the core component of the circuit breaker. It is a sealed chamber that contains contacts and utilizes a vacuum to extinguish the arc produced during circuit interruption. The vacuum interrupter provides reliable and efficient breaking and making of electrical circuits.
2.Operating Mechanism: The operating mechanism is responsible for opening and closing the contacts of the circuit breaker. It typically includes a spring mechanism, operating rods, and associated linkages. 3.The operating mechanism can be manual or motorized, depending on the specific model of the circuit breaker.
4.Control Panel: The control panel houses the control and monitoring devices for the circuit breaker. It includes control switches, indicators, and protection relays. The control panel allows for manual control of the circuit breaker, as well as monitoring its status and protection functions.
5.Insulation System: The insulation system of the ZW32-12 vacuum circuit breaker ensures the electrical insulation between the live parts and the grounded components. It includes insulation materials, such as insulating bushings, insulating barriers, and insulation supports, to prevent electrical arcing and ensure the safe operation of the circuit breaker.
6.Enclosure: The circuit breaker is housed in an enclosure, which provides mechanical protection and environmental isolation. The enclosure is typically made of high-quality materials, such as metal or composite materials, to ensure durability and protection against external influences.
7.Auxiliary Contacts: The ZW32-12 vacuum circuit breaker may include auxiliary contacts for auxiliary control and signaling purposes. These contacts can be used for remote indication, control circuits, or interlocking with other equipment.
Condition:
1.High Altitude Compatibility: The ZW32-12 vacuum circuit breaker is designed to operate reliably at altitudes of up to 2000 meters. It is specifically engineered to withstand the unique environmental conditions associated with high-altitude installations, ensuring its performance and safety in such settings.
2.Wide Temperature Range: The ZW32-12 circuit breaker is capable of operating in a wide ambient air temperature range, from -45 °C to +40 °C. It is built to handle extreme temperatures and maintain its functionality, providing reliable protection and control even in harsh climatic conditions. Moreover, it is designed to accommodate daily temperature differences of up to 25 °C, further ensuring its suitability for dynamic temperature environments.
3.Wind Resistance: With a wind speed limit of up to 35 m/s, the ZW32-12 circuit breaker demonstrates excellent wind resistance. It can withstand strong winds commonly experienced in various outdoor installations, including substations and power distribution systems. This feature guarantees the stability and reliability of the circuit breaker's operation, even in windy conditions.
4.Resilience to Harsh Environments: The ZW32-12 circuit breaker is designed for installation in environments that are free from flammable, explosive dangerous chemicals, corrosive substances, and violent vibrations. It is constructed with materials that resist corrosion and can withstand challenging conditions, ensuring its longevity and performance in harsh industrial or outdoor settings.
Technical Parameter:
Serial No. | Parameter | Unit | Data | |||||||||
1 | Rated voltage | kV | 12 | |||||||||
2 | Insulation level of Fracture | Working Frequency(Dry Test/Wet Test) | 48 | |||||||||
Voltage of Lightning Shock Test (Peak) | 85 | |||||||||||
3 | Level of Insulation to ground/phase to phase | Working Frequency | Dry Test | 42 | ||||||||
Wet Test | 34 | |||||||||||
Voltage of Lightning Shock Test (Peak) | 75 | |||||||||||
4 | Rated Current | A | 630 | |||||||||
5 | Rated thermal stability current (Effective value) | kA | 20 | |||||||||
6 | Rated short-circuit breaking current (Effective value) | 25 | ||||||||||
7 | Rated thermal stability time | s | 4 | |||||||||
8 | Rated short-circuit closing current(Peak) | kA | 63 | |||||||||
9 | Rated dynamic stability current (Peak) | |||||||||||
10 | Mechanical lifetime | times | 10000 | |||||||||
11 | Opening rated current | 1000 | ||||||||||
12 | Surrounding air temperature | Highest Temperature | ℃ | -55 | ||||||||
Lowest Temperature | +60 | |||||||||||
Difference ofMaximum daily temperature | K | ≤25 | ||||||||||
13 | Altitude | m | ≤2500 | |||||||||
14 | Humidity | Average of daily relative humidity | % | ≤95 | ||||||||
Average of monthly relative humidity | ≤90 | |||||||||||
15 | Earthquake-resistant capacity | Horizontal acceleration | g | 0.25 | ||||||||
Ground vertical acceleration | 0.125 | |||||||||||
Safety Factor | / | 1.67 | ||||||||||
16 | Wind Speed | m/s | ≤35 | |||||||||
17 | Ice Thickness | mm | ≤20 | |||||||||
It will double the effect using when the circuit breakers used with isolation disconnector.
![]() |
630A 1250A High Voltage Electrical Sectionalizer With Zero-Sequence Sensors Matching With Outdoor Hookstick Images |